| Chassis |
2U Rackmount |
| Model |
CSV-GT214BC-R2K21BP |
| Dimensions and Weight |
| Height |
3.46″ (88 mm) |
| Width |
17.67″ (449 mm) |
| Depth |
28″ (711.2 mm) |
| Package |
9.76″ (H) x 24.65″ (W) x 45.28″ (D) |
| Weight |
- Gross Weight: 88 lbs (39.9 kg)
- Net Weight: 68 lbs (30.8 kg)
|
| Available Color |
Silver |
| Front Panel |
| LED |
HDD activity LED, Network activity LEDs, Power status LED, Universal Information (UID) LED |
| Buttons |
Power On/Off button, UID button |
| Expansion Slots (per Node) |
| PCI-Express (PCIe) Configuration |
- Default: 2 PCIe 5.0 x16 (in x16) AIOM slots (OCP 3.0 compatible)
- View AOC Options
|
| Drive Bays / Storage (per Node) |
| Drive Bays Configuration |
- Default: Total 6 bays, 6 front hot-swap 2.5″ PCIe 5.0 x4 NVMe drive bays
- View NVMe Options
|
| M.2 |
2 M.2 PCIe 5.0 x4 NVMe slots (M-key 22110(default)/2280; VROC required for RAID) |
| System Cooling |
| Fans |
2x 16K RPM Heavy Duty 8cm Fan(s) |
| Power Supply |
| 2x 2200W Redundant (1 + 1) Titanium Level (96%) power supplies |
| Dimension (WxHxL) |
106.5 x 84 x 245.3 mm |
| Input |
- 100-127Vdc (1200W for the Rest of the World)
- 1200W: 100-127Vac / 50-60Hz
- 2090W: 180-220Vac / 50-60Hz (For UL/cUL Only)
- 200-220Vdc (1800W for the Rest of the World)
- 200-220Vdc (2090W for North America – UL & cUL)
- 1800W: 200-220Vac / 50-60Hz
- 220-230Vdc (1980W for the Rest of the World)
- 1980W: 220-230Vac / 50-60Hz
- 220-240Vdc (2200W for North America – UL & cUL)
- 2200W: 220-240Vac / 50-60Hz (For UL/cUL Only)
- 230-240Vdc (2090W for the Rest of the World)
- 2090W: 230-240Vdc / 50-60Hz (for CQC only)
- 2090W: 230-240Vac / 50-60Hz (for TUV/CB)
|
| +12V |
- Max: 100A / Min: 0A (100Vac-127Vac)
- Max: 174.17A / Min: 0A (180Vdc-220Vdc) (For UL/cUL only)
- Max: 174.17A / Min: 0A (180Vac-220Vac) (For UL/cUL Only)
- Max: 150A / Min: 0A (200Vac-220Vac)
- Max: 165A / Min: 0A (220Vac-230Vac)
- Max: 183.3A / Min: 0A (220Vac-240Vac)
- Max: 183.3A / Min: 0A (220Vac-240Vac) (For UL/cUL only)
- Max: 174.17A (230Vac-240Vac)
|
| 12V SB |
Max: 2A / Min: 0A |
| Output Type |
Backplanes (gold finger) |
| Operating Environment |
| ROHS |
RoHS Compliant |
| Environmental Spec. |
- Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
- Non-operating Temperature: -30°C to 60°C (-22°F to 140°F)
- Operating Relative Humidity: 8% to 80% (non-condensing)
- Non-operating Relative Humidity: 8% to 90% (non-condensing)
|