| Chassis |
| Form Factor |
1U Rackmount |
| Model |
CSE-HS101-R000NFP |
| Dimensions and Weight |
| Height |
1.7″ (43 mm) |
| Width |
17.2″ (437 mm) |
| Depth |
30.66″ (778.7 mm) |
| Package |
8.82″ (H) x 26.46″ (W) x 43.31″ (D) |
| Weight |
- Gross Weight: 41.4 lbs (18.8 kg)
- Net Weight: 19.2 lbs (8.7 kg)
|
| Available Color |
Silver |
| Front Panel |
| LED |
- HDD activity
- LAN1 activity
- Power status
- System information
|
| Buttons |
|
| Expansion Slots |
| PCI-Express (PCIe) Configuration |
- Default
- 1 PCIe 5.0 x16 FHHL slot
- 2 PCIe 5.0 x16 FHFL slots
- 1 PCIe 5.0 x16 AIOM slot (OCP 3.0 compatible)
- View AOC Options
|
| CXL Support |
Up to 4 CXL 2.0 x16 devices |
| Drive Bays / Storage |
| Drive Bays Configuration |
- Default: Total 8 bays
- 8 front hot-swap 2.5″ NVMe*/SATA* drive bays
- Option A: Total 12 bays
- 12 front hot-swap 2.5″ NVMe*/SATA* drive bays
- (*NVMe/SATA support may require additional storage controller and/or cables, please see the optional parts list for details)
- View NVMe Options
- View Drive Options
|
| M.2 |
|
| System Cooling |
| Fans |
8 counter-rotating 40x40x56mm Fan(s) |
| Power Supply Options |
| 2x 1600W Redundant (1 + 1) Titanium Level (96%) power supplies |
| Dimension (WxHxL) |
73.5 x 40 x 265 mm |
| Input |
1000W: 100-127Vac
1000W: 100-127Vac / 50-60Hz
1600W: 200-240Vac
1600W: 200-240Vac / 50-60Hz
1600W: 200-240Vdc / 50-60Hz (for CQC only) |
| +12V |
Max: 83.3A / Min: 0A (100Vac-127Vac)
Max: 133.3A / Min: 0A (200Vac-240Vac) |
| 12V SB |
Max: 3.5A / Min: 0A |
| Output Type |
Backplanes (gold finger) |
| 2x 1300W Redundant (1 + 1) Gold (Certification Pending) Level power supplies |
| Dimension (WxHxL) |
73.5 x 40 x 265 mm |
| Input |
1300W: -44–65Vdc |
| +12V |
Max: 108.3A / Min: 0A |
| 12V SB |
Max: 2.1A |
| Output Type |
Backplanes (gold finger) |
| 2x 2600W Redundant (1 + 1) Titanium Level (96%) power supplies |
| Dimension (WxHxL) |
73.5 x 40 x 265 mm |
| Input |
2600W: 200-240Vac
2600W: 200-240Vdc (For CQC Only)
2600W: 200-240Vac / 50-60Hz
2600W: 200-240Vdc / 50-60Hz (for CQC only) |
| +12V |
Max: 216A / Min: 0A (11.4Vdc-12.6Vdc) (12V output)
Max: 216A / Min: 0A (200Vac-240Vac) |
| 12V SB |
Max: 3.5A |
| Output Type |
Backplanes (gold finger) |
| 2x 1200W Redundant (1 + 1) Titanium Level (96%) power supplies |
| Dimension (WxHxL) |
73.5 x 40 x 265 mm |
| Input |
800W: 100-127Vac
800W: 100-127Vac / 50-60Hz
1200W: 200-240Vac
1200W: 200-240Vac / 50-60Hz
1200W: 230-240Vdc / 50-60Hz (for CCC only) |
| +12V |
Max: 66.7A / Min: 0A (100Vac-127Vac)
Max: 83A / Min: 0A (100Vac-127Vac)
Max: 100A / Min: 0A (200Vac-240Vac)
Max: 100A / Min: 0A (230Vdc-240Vdc) (for CCC only) |
| 12V SB |
Max: 2.1A / Min: 0A |
| Output Type |
Backplanes (gold finger) |
| 2x 2000W Redundant (1 + 1) power supplies |
| Dimension (WxHxL) |
73.5 x 40 x 265 mm |
| Input |
2000W: -48–60Vdc / 50-60Hz |
| +12V |
Max: 166.6A / Min: 0A |
| 12V SB |
Max: 4A / Min: 0A |
| Output Type |
Backplanes (gold finger) |
| 2x 2000W Redundant (1 + 1) Titanium Level (96%) power supplies |
| Dimension (WxHxL) |
73.5 x 40 x 265 mm |
| Input |
1000W: 100-127Vac / 50-60Hz
1800W: 200-220Vac / 50-60Hz
2700W: 200-240Vac
1980W: 220-230Vac / 50-60Hz
2000W: 220-240Vac / 50-60Hz (for UL only)
2000W: 230-240Vac / 50-60Hz
2000W: 230-240Vdc / 50-60Hz (for CQC only) |
| +12V |
Max: 83A / Min: 0A (100Vac-127Vac)
Max: 150A / Min: 0A (200Vac-220Vac)
Max: 225A / Min: 0A (200Vac-240Vac)
Max: 165A / Min: 0A (220Vac-230Vac)
Max: 166A / Min: 0A (230Vac-240Vac) |
| 12V SB |
Max: 3.5A / Min: 0A |
| Output Type |
Backplanes (gold finger) |
| Operating Environment |
| Environmental Spec. |
- Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
- Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
- Operating Relative Humidity: 8% to 90% (non-condensing)
- Non-operating Relative Humidity: 5% to 95% (non-condensing)
|
| Environmental / Recycling |
Recycle: Return Server-End of Life Product |